A manual, nosepiece type microscope which meets the various needs of observation, inspection, research and analysis across a wide range of industrial fields. Higher NA and a longer working distance than ever before means superior optical performance and efficient digital imaging.
Max. sample size: 150 x 150 mm.
Compatible with brightfield, darkfield, simple polarizing, DIC, epifluorescence and two-beam interferometry observations. It supports diverse and advanced research, analysis and inspection.
* Select suitable lens for each observation
Newly developed CFI60-2 series provides the ultimate in long working distance levels and the most advanced chromatic aberration in a light weight body
CFI60-2 series offers higher NA and longer working distances than ever before.
Objectives for brightfield observation (epi)
Information about the objective in use is detected and displayed on the camera control unit. In addition, the information is automatically converted into appropriate calibration data when changing magnification.
An environmentally friendly version of the LV150NL which consumes less power through long-life LED illumination is also available.
Base unit: | Maximum sample height: 38 mm (when used with LVNU5AI U5AI nosepiece and LV-S32 3x2 stage / LV-S64 6x4 stage) * 73 mm when used with one column riser 12V50W internal power source for dimmer, coarse and fine adjustment knobs Left: coarse and fine adjustment / Right: fine adjustment, 40 mm stroke Coarse adjustment: 14 mm/turn (with torque adjustment, refocusing mechanism) Fine adjustment: 0.1 mm/turn (1 μm/graduation) Stage mounting hole intervals: 70 x 94 (fixed by 4-M4 screw) |
---|---|
Nosepieces: | C-N6 ESD Sextuple Nosepiece ESD LV-NU5 Universal Quintuple Nosepiece ESD LV-NBD5 BD Quintuple Nosepiece ESD LV-NU5I Intelligent Universal Quintuple Nosepiece ESD |
Episcopic Illuminator: | LV-UEPI-N LV-LH50PC 12V50W Precentered Lamphouse Bright/darkfield switch and linked aperture stop (centerable), field diaphragm (centerable) Accepts ø 25 mm filter (NCB11, ND16, ND4), polarizer/analyzer, plate, excitation light balancer; equipped with noise terminator LV-UEPI2 LV-LH50PC 12V50W Precentered Lamphouse HG precentered fiber illuminator: C-HGFIE (with light adjustment) *option Bright/darkfield switch and linked aperture stop (centerable), field diaphragm (centerable), automated optical element switching feature matched to brightfield, darkfield, and epi-fluorescence switch Accepts ø 25 mm filter (NCB11, ND16, ND4), polarizer/analyzer, λ plate, excitation light balancer; equipped with noise terminator |
Eyepiece tubes: | LV-TI3 trinocular eyepiece tube ESD (Erected image, FOV: 22/25) LV-TT2 TT2 tilting trinocular eyepiece tube (Erected image, FOV: 22/25) C-TB binocular tube (Inverted image, FOV: 22) P-TB Binocular Tube (Inverted image, FOV: 22) P-TT2 Trinocular Tube (Inverted image, FOV: 22) |
Stages: | LV-S32 3x2 stage (Stroke: 75 x 50 mm with glass plate) ESD compatible LV-S64 6x4 stage (Stroke: 150 x 100 mm with glass plate) ESD compatible LV-S6 6x6 stage (Stroke: 150 x 150 mm) ESD compatible |
Eyepieces: | CFI eyepiece series |
Objective lenses: | Industrial Microscope CFI60-2/CFI60 optical system Objective lens series: Combinations in accordance with the observation method |
ESD performance: | 1000 to 10V, within 0.2 sec. (excluding certain accessories) Power consumption: 1.2A/75W |
Weight: | Approximately 8.6kg |